Inspection

Support the motorcycle level surface. Remove the windscreen (page 2-7).

Turn the ignition switch to "ON" and measure the voltage between the following terminals of the bank angle sensor connector with the connector connected.

TERMINAL

STANDARD

White/Black <+) - Green (-)

Battery voltage

RedA/Vhite (+) - Green H

3P CONNECTOR

BANK ANGLE SENSOR

BANK ANGLE SENSOR

CONNECTOR

CONNECTOR

Turn the ignition switch to "OFF".

Do nor disconnect Remove the screws and bank angle sensor.

the bank angle sensor connector during inspection.

Place the bank angle sensor horizontal as shown, and turn the ignition switch to "ON".

The bank angle sensor is normal if the engine stop relay clicks and power supply is closed.

Incline the bank angle sensor approximately 60 degrees to the left or right with the ignition switch turned to "ON".

The bank angle sensor is normal if the engine stop relay clicks and power supply is open.

If you repeat this test, first turn the ignition switch to "OFF", then turn the ignition switch to "ON".

Was this article helpful?

0 0
DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.