Replacementair Bleeding

Remove the radiator cap.

ANTIFREEZE ] SOLUTION

(ETHYLENE GLYCOL BASE SOLUTION)

ANTIFREEZE ] SOLUTION

LOW MINERAL OR DISTILLED WATER

COOLANT

RADIATOR CAP

L(Jr

Remove the lower cowl (page 2-4).

Remove the drain holt on the water pump cover and drain the coolant.

Remove the cylinder drain bolt and drain the coolant from the cylinder.

Reinstall the drain bolt with the new sealing washer. Tighten the water pump drain bolt to the specified torque.

Remove the right air duct (page 2-7)

Disconnect the siphon hose from the radiator.

Drain the reserve tank coolant.

Empty the coolant and rinse the inside of the reserve tank with water.

Reinstall the radiator siphon hose.

√ĄcEiSKl

Fill the system with the recommended coolant through the filler opening up to the filler neck.

Remove the radiator reserve tank cap and fill the reserve tank to the upper level line.

Bleed air from the system as follow:

1. Shift the transmission into neutral. Start the engine and let it idle for 2 3 minutes.

2. Snap the throttle three to four times to bleed air from the system.

3. Stop the engine and add coolant to the proper level if necessary. Reinstall the radiator cap.

4. Check the level of coolant in the reserve tank and fill to the upper level if it is low.

Was this article helpful?

0 0
DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.