No

Replace the neutral switch.

3. Starting circuit cut-off relay (diode)

Disconnect the starting circuit cut-off relay coupler from the wire harness. ►Connect the pocket tester (Q x 1) to the starting circuit cut-off relay coupler as shown.

Check the starting circuit cut-off relay for continuity.

Positive tester probe ^

black/red ® Negative tester probe ^

sky blue (2

Positive tester probe ^

sky blue (2 Negative tester probe ^

Continuity

No continuity

When you switch the positive and negative tester probes, the readings in the above chart will be reversed.

easgg75s easggbg1

' Are the tester readings correct?

Was this article helpful?